WatchGuy Photo Library

Back to Overview

Omega Seamaster 300 166.0324 Calibre 562



the amplitude is so weak that the timegrapher doesn't pick up the signal





second hand pinion bent

wrong screws in automatic device bridge

very odd - the screws of the automatic device have been blued - probably due to some overheating??

the rotor post also looks to have suffered some heat damage


wrong screws in pallet cock



the second hand pinion is slightly bent, and I reshape it


wrong screw in setting lever holding spring





new Omega original screws and wheels


the cap jewel is the wrong size, and has a very rough surface

the correct cap jewel

the hairspring is deformed

the re-shaped hairspring is nice and flat again