WatchGuy Photo Library

Back to Overview

Universal Geneve 22258 Calibre 481

































the hour recorder hammer spring is limp, and doesn't touch the hour recorder hammer




broken hour recorder hammer spring

the hour hammer spring is broken





















the base movement is back together and ticking

super performance of the base movement!





the new spring is a mirror image of the old one, so I have to put the pin to the other side

I try to push the pin out, but it's part of the spring and machined out , so it can't be pushed

I put a new pin on the bottom side of the spring

not quite there yet - the pin that sticks out has to be taken off, and I have to sink the hole for the screw



the hammer spring screw hole needs to be sunk a bit more

the month pusher lever needs polishing


hour recorder hammer spring screw hole sunk deeper

now the screw sits flush




yet another problem - the second hand tube is broken ...

I will replace the old, split tube with a new tube

the hand is broached to fit the new tube

the hand is soldered to the tube

then the tube length is corrected

the central second hand with the new tube


just to bother me some more, the sub-second hand tube is split as well

as the pressure on that tube isn't that great, I just solder the split shut